Pressure Products
Filters 99,312 Results
$648.72
Subject to factory lead times
$25.37
Subject to factory lead times
$23.84
Subject to factory lead times
$26.62
Subject to factory lead times
$21.25
Subject to factory lead times
$20.32
Subject to factory lead times
$157.72
Subject to factory lead times
$52.47
Subject to factory lead times
$591.01
Subject to factory lead times
$219.03
Subject to factory lead times
$671.22
Subject to factory lead times
$370.93
Subject to factory lead times
$648.72
Subject to factory lead times
$25.37
Subject to factory lead times
$23.84
Subject to factory lead times
$26.62
Subject to factory lead times
$21.25
Subject to factory lead times
$20.32
Subject to factory lead times
$157.72
Subject to factory lead times
$52.47
Subject to factory lead times
$591.01
Subject to factory lead times
$219.03
Subject to factory lead times
$671.22
Subject to factory lead times
$370.93
Subject to factory lead times
- psi (pounds per square inch): North American standard for almost everything. bar: European/metric default, roughly equal to atmospheric pressure (1 bar ≈ 14.5 psi). kPa (kilopascal): SI unit, 1 kPa ≈ 0.145 psi. inH2O (inches of water column): used for very low pressures like HVAC ductwork, where 1 inH2O ≈ 0.036 psi. Conversion table: 1 bar = 14.5 psi = 100 kPa = 401.5 inH2O. Most transmitters let you select the display units in configuration.
- Gauge: visual local indication, dial face, no electrical output. Transmitter: 4-20 mA or digital output to the control system, continuous remote reading. Transducer: similar to transmitter, sometimes with raw mV or 0-5 V output instead of 4-20 mA loop-powered. Switch: closes a contact at a setpoint, no continuous reading. Each one has its place - gauge for local indication, transmitter for control, transducer for OEM systems, switch for alarms and interlocks.
- Gauge pressure is measured relative to atmospheric pressure. It reads zero at atmospheric, positive when above, vacuum when below. This is what almost every industrial gauge and transmitter shows. Absolute pressure is measured relative to a true vacuum, so it's always positive. It's used for altitude measurement, vacuum work, and some scientific applications. Differential pressure is the difference between two pressures, used for flow across an orifice, filter loading, level in pressurized tanks, and any other DP measurement. Spec the wrong reference and your readings are off by an entire atmosphere.

Download Line Card
Download the NISCO Inc. Line Card to view all brands and products NISCO Inc. distributes and/or represents.
About NISCO Inc.
NISCO offers a wide range of pressure gauges & instruments, diaphragm seals, thermometers, valves, and flow control products to the industrial and commercial marketplaces, as well as other resellers like ourselves. We can also provide other value-added services such as gauge repair, NIST traceable calibration, diaphragm seal assembly, and valve automation. NISCO takes pride in providing extensive product knowledge, helpful customer service, and market competitive pricing to help fit whatever need you may have because it is our goal to be regarded by our customers as the best supplier of pressure, temperature, and flow control products.